KTPK (PACKAGED TRANSFORMER SUBSTATION OF THE CABIN TYPE)

| High voltage complete devices

DescriptionTechnical data

Description

The packaged transformer substations of the cabin type with the 6 or10 kV voltage (herein after KTPK) are designed for power supply of agricultural users, separate settlements and industrial facilities, construction operations and various industrial activities in areas with moderate or cold climate.

The KTPK substations can not be operated under the following conditions:

  • under conditions of jolting, vibrations and impact effects;
  • power infeed on the lowest voltage side;
  • installation in explosion and fire hazardous areas according to the Electrical installation code and special environments according to GOST 24682-81.

Normal functioning of the substations is provided under the following conditions:

  • installation altitude above the sea level – not more than 1000m;
  • installation in explosion and fire hazardous areas according to the Electrical installation code and special environments according to GOST 24682-81.

Parameters

Parameter name

Parameter value

Power transformer capacity, kVA

25; 40; 63; 100; 160; 250; 400; 630; 1000; 1250; 1600; 2500

Nominal voltage on the high-voltage side, kV

6; 10

The highest operating voltage on the high-voltage side, kV

7,2; 12

Nominal voltage on the low-voltage side, kV

0,4

Short-time thermal current on the high-voltage side , kA

20

Short time electrodynamic current on the high-voltage side , kA

51

Input circuit insulation resistance on the high-voltage side , MOhm, min

1000

Classification

Classification

Version

According to the type of the power transformer

With an oil transformer;

with a dry transformer

According to the number of power transformers

One;

two o more transformers.

According to the number of modules

Single-module;

multi-module

According to the type of neutral terminal of the power transformer on the lowest voltage side

Earth and neutral connected;

with an insulated neutral (without a neutral bus)

According to diagrams of connection to circuits

Dead-end;

through-type

According to the phase-displacement group of power transformers

Yн / D, Y / Yн, D / Yн

According to the type of connection to voltage input devices and low voltage switchgears

By means of cables;

copper uninsulated busbars;

Aluminum uninsulated busbars

According to the type of the high-voltage terminal

Air;

cable

According to the type of the low-voltage terminal

Air;

cable

According to the types of automatic switches

Fixed;

plug-in type;

Draw-out type

Technical data